Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 228
Filtrar
1.
J Cardiovasc Dev Dis ; 11(4)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38667735

RESUMO

(1) Background: Early reintervention increases the risk of infection of cardiac implantable electronic devices (CIEDs). Some operators therefore delay lead repositioning in the case of dislocation by weeks; however, there is no evidence to support this practice. The aim of our study was to evaluate the impact of the timing of reoperation on infection risk. (2) Methods: The data from consecutive patients undergoing lead repositioning in two European referral centers were retrospectively analyzed. The odds ratio (OR) of CIED infection in the first year was compared among patients undergoing early (≤1 week) vs. delayed (>1 week to 1 year) reoperation. (3) Results: Out of 249 patients requiring CIED reintervention, 85 patients (34%) underwent an early (median 2 days) and 164 (66%) underwent a delayed lead revision (median 53 days). A total of nine (3.6%) wound/device infections were identified. The risk of infection was numerically lower in the early (1.2%) vs. delayed (4.9%) intervention group yielding no statistically significant difference, even after adjustment for typical risk factors for CIED infection (adjusted OR = 0.264, 95% CI 0.032-2.179, p = 0.216). System explantation/extraction was necessary in seven cases, all being revised in the delayed group. (4) Conclusions: In this bicentric, international study, delayed lead repositioning did not reduce the risk of CIED infection.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38286881

RESUMO

BACKGROUND: The use of an antibacterial envelope is cost-effective for patients at high risk of developing cardiac implantable electronic device (CIED) infection. The identification of these high-risk patients may be facilitated using a clinical risk score. The aim of the current study is to evaluate the PADIT score for identifying high-risk patients in patients undergoing a CIED procedure in a tertiary academic center. METHODS: This was a retrospective single-center study of consecutive patients undergoing a CIED procedure between January 2016 and November 2021. Patients who received an antibacterial envelope were excluded from this study. The primary endpoint was hospitalization for a CIED infection in the first year after the procedure. RESULTS: A total of 2333 CIED procedures were performed in the study period (mean age 61.6 ± 16.3 years, male sex 64.5%, previous CIED infection 1.7%, immunocompromised 5.4%). The median PADIT score was 4 (interquartile range, 2-6). CIED infection occurred in 10 patients (0.43%). The PADIT score had good discrimination in predicting major CIED infection (C-statistic 0.70; 95% confidence interval [CI] 0.54 to 0.86, P = 0.03). Using an optimal PADIT score cut-off value of 7, the risk of CIED infection was higher in the patients with a PADIT score of ≥ 7 in comparison to those with a lower PADIT score (1.23% vs. 0.26%, P = 0.02; odds ratio 4.8, 95% CI 1.4 to 16.6, P = 0.01). CONCLUSIONS: The PADIT score is a clinically useful score for identifying patients at high risk of developing CIED infection. The use of an antibacterial envelope in these high-risk patients may be cost-effective.

3.
J Clin Med ; 12(23)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38068348

RESUMO

BACKGROUND: Insulin resistance plays an important role in the development of post-transplantation diabetes mellitus (PTDM) in kidney transplant recipients (KTRs). Current methods for the direct determination of insulin resistance are complicated and invasive. Therefore, this study aimed to investigate the relevance of indirect insulin resistance indices in relation to the development of PTDM in KTRs. METHODS: We included 472 stable outpatient KTRs without diabetes at baseline from a prospective cohort study. Four indirect insulin resistance indices, namely homeostasis model assessment-insulin resistance (HOMA-IR), visceral adiposity index (VAI), lipid accumulation product (LAP), and triglycerides-glucose (TyG) index, were assessed. We analyzed each measure using the receiver operating characteristic (ROC) curve for PTDM development. The optimal cut-off value for each parameter was determined using the Youden index. RESULTS: After a median of 9.6 years (interquartile range (IQR) 6.6-10.2) of follow-up, 68 (14%) KTRs developed PTDM. In Cox regression analyses, all indirect insulin resistance indices associated with incident PTDM were independent of potential confounders. ROC curve was 0.764 (95% CI, 0.703-0.826) for HOMA-IR, 0.685 (95% CI, 0.615-0.757) for VAI, 0.743 (95% CI, 0.678-0.808) for LAP, and 0.698 (95% CI, 0.629-0.766) for TyG index, with respective optimal cut-off values of 2.47, 4.01, 87.0, and 4.94. CONCLUSIONS: Indirect insulin resistance indices can be used to predict incident PTDM in KTRs. In addition to HOMA-IR, insulin-free surrogates of insulin resistance might serve as useful methods to identify KTRs at risk of PTDM, thus obviating the necessity to measure insulin.

4.
J Cardiovasc Dev Dis ; 10(11)2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37998501

RESUMO

BACKGROUND: Chronic limb-threatening ischemia (CLTI) is associated with high rates of long-term cardiovascular mortality. Exercise stress testing to detect obstructive coronary artery disease (CAD) can be difficult in this subset of patients due to inability to undergo exercise testing, presence of balanced ischemia and severe coronary artery calcification (CAC). AIM: To test the feasibility of regadenoson stress dynamic perfusion computed tomography (DPCT) in CLTI patients. METHODS: Between 2018 and 2023, coronary computed tomography angiography (CTA) and, in the case of a calcium score higher than 400, DPCT, were performed in 25 CLTI patients with a history of endovascular revascularization. RESULTS: Of the 25 patients, 19 had a calcium score higher than 400, requiring DPCT image acquisition. Obstructive CAD could be ruled out in 10 of the 25 patients. Of the 15 CTA/DPCT+ patients, 13 proceeded to coronary angiography (CAG). Revascularization was necessary in all 13 patients. In these 13 patients, vessel-based sensitivity and specificity of coronary CTA/DPCT as compared to invasive evaluation was 75%, respectively. At follow-up (27 ± 21 months) there was no statistically significant difference in all-cause mortality between CTA/DPCT- positive and -negative patients (p = 0.065). CONCLUSIONS: Despite a high prevalence of severe CAC, coronary CTA complemented by DPCT may be a feasible method to detect obstructive and functionally significant CAD in CLTI patients.

6.
Eur Heart J Case Rep ; 7(9): ytad405, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37712004

RESUMO

Background: Accessory pathways (APs) with multiple atrial insertions are often unrecognized and associated with initial catheter ablation (CA) failure. Recently, a novel dipole charge density mapping (DCDM) system was developed that allows mapping of complex arrhythmias based on a single beat. We aim to present the first-in-human report of 3D visualization of a single AP with two atrial insertion sites using high-resolution DCDM. Case summary: A 43-year-old man with recurrent symptomatic atrioventricular re-entrant tachycardia and previously failed CA attempts underwent repeated CA using DCDM. Dipole charge density mapping identified two quasi-simultaneous early atrial activation sites at the left lateral and left anterolateral atrial aspects of the mitral annulus, suggesting the presence of a single AP with dual atrial insertion sites. Successful radiofrequency CA was performed at the mid-body of the AP. Discussion: The true prevalence of APs with multiple atrial insertion sites may be higher than currently reported. This is the first-in-human report of 3D visualization of a single AP with two atrial insertion sites using high-resolution DCDM. Dipole charge density mapping allows the accurate localization of APs with multiple insertion sites based on a single beat.

7.
J Cardiovasc Electrophysiol ; 34(12): 2472-2483, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37767745

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is a pivotal part of ablative therapy for atrial fibrillation (AF). Currently, there are multiple techniques available to realize PVI, including: manual-guided cryoballoon (MAN-CB), manual-guided radiofrequency (MAN-RF), and robotic magnetic navigation-guided radiofrequency ablation (RMN-RF). There is a lack of large prospective trials comparing contemporary RMN-RF with the more conventional ablation techniques. This study prospectively compared three catheter ablation techniques as treatment of paroxysmal AF. METHODS: This multicenter, prospective study included patients with paroxysmal AF who underwent their first ablation procedure. Procedural parameters (including procedural efficiency), complication rates, and freedom of AF during 12-month follow-up, were compared between three study groups which were defined by the utilized ablation technique. RESULTS: A total of 221 patients were included in this study. Total procedure time was significantly shorter in MAN-CB (78 ± 21 min) compared to MAN-RF (115 ± 41 min; p < .001) and compared to RMN-RF (129 ± 32 min; p < .001), whereas it was comparable between the two radiofrequency (RF) groups (p = .062). A 3% complication rate was observed, which was comparable between all groups. At 12-month follow-up, AF recurrence was observed in 40 patients (19%) and was significantly lower in the robotic group (MAN-CB 19 [24%], MAN-RF 16 [23%], RMN-RF 5 [8%] AF recurrences, p = .045) (multivariate hazard ratio of RMN-RF on AF recurrence 0.32, 95% confidence interval: 0.12-0.87, p = .026). CONCLUSION: RMN-guided PVI results in high freedom of AF in patients with paroxysmal AF, when compared to cryoablation and manual RF ablation. Cryoablation remains the most time-efficient ablation technique, whereas RMN nowadays has comparable efficiency with manual RF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Procedimentos Cirúrgicos Robóticos , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Fenômenos Magnéticos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
9.
Int J Cardiol ; 390: 131205, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37482094

RESUMO

BACKGROUND: The presence of an untreated chronic total coronary occlusion (CTO) is associated with a higher risk of ventricular arrhythmias (VAs). This increased risk may be modulated by the presence of an existing scar. OBJECTIVES: To evaluate whether scar size is associated with VA in patients with an implantable cardioverter-defibrillator (ICD) and a CTO. METHODS: In this retrospective study we included patients with a CTO that received an ICD between 2005 and 2015. Scar size was estimated using the Selvester QRS score on a baseline 12­lead ECG. The primary endpoint was any appropriate ICD therapy. RESULTS: Our study population comprised 148 CTO patients with a median scar size at baseline of 18% (IQR, 9-27%). Patients with a scar size ≥18% more often had a CTO located in the left anterior descending artery and a higher proportion of poor left ventricular function (<35%) and infarct-related CTO compared to patients with a smaller scar size (<18%). During a median follow-up of 35 months (interquartile range [IQR], 8-60 months), 42 patients (28%) received appropriate ICD therapy. The cumulative 5-year event rate was higher in the patients with a large scar in comparison to those with a smaller or no scar (36% versus 19%, P = 0.04). Multivariable Cox regression analysis demonstrated that large scar and diabetes mellitus were independent factors associated with appropriate ICD therapy. CONCLUSION: In ICD recipients with an untreated CTO, a larger scar is an independent factor associated with an increased risk of VA.


Assuntos
Oclusão Coronária , Desfibriladores Implantáveis , Humanos , Oclusão Coronária/diagnóstico , Oclusão Coronária/diagnóstico por imagem , Estudos Retrospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Desfibriladores Implantáveis/efeitos adversos , Fatores de Risco , Resultado do Tratamento
10.
Pacing Clin Electrophysiol ; 46(7): 771-781, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37260105

RESUMO

BACKGROUND: Catheter ablation (CA) remains challenging due to suboptimal success rates in persistent atrial fibrillation (AF). Existing mapping technologies cannot reliably distinguish sources in this patient population. Recently, the novel electrographic flow (EGF) mapping system was developed using a modified Horn-Schunk optical flow algorithm to detect and quantify patterns of electrical wavefront propagation in the atria. OBJECTIVES: To test the hypothesis that targeted source ablation based on EGF mapping is superior to empiric AF ablation. METHODS: We included all consecutive patients undergoing EGF guided ablation for persistent AF. All patients underwent pulmonary vein isolation (PVI) and were treated with the same EAM system (CARTO). The outcome of PVI+EGF guided CA was compared with data of PVI-only procedures (PVI-only group) and PVI plus additional empiric adjunctive linear and substrate ablations (PVI+LINES group). 12-months outcome as freedom from AF and atrial tachycardia/flutter (AT/AFL), procedural safety and efficiency characterized by procedure duration, fluoroscopy use, radiofrequency applications and duration, were analyzed. Both intention-to-treat and per protocol analysis were conducted. RESULTS: A total number of 70 patients (39 in PVI+EGF, 16 in PVI-only and 15 patients in PVI+LINES group) were enrolled. Intention-to-treat analysis showed fewer AF recurrences in PVI+EGF as compared with the PVI-only or PVI+LINES groups at 12 months (25.6% vs. 62.5% vs. 53.3%, p = .02). There were no differences in AT/AFL recurrence (17.9% vs. 37.5% vs. 20.0%, p = .37). Procedure times were longer in PVI+EGF group (p < .01), and there were no differences in fluoroscopy use (p = .67). CONCLUSION: Our data suggest that patients treated with EGF-guided CA developed fewer AF recurrences. Although the procedure times are longer, it seems to be safe and offers a more targeted, patient-specific ablation strategy beyond PVI than adjunctive empiric lines and substrate ablation in this complex group of patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Fator de Crescimento Epidérmico , Resultado do Tratamento , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Recidiva
11.
Heart Rhythm O2 ; 4(6): 391-400, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37361617

RESUMO

Background: Electrographic flow (EGF) mapping enables the dynamic detection of functional or active atrial fibrillation (AF) sources outside the pulmonary veins (PVs), and the presence or absence of these sources offers a novel framework for classifying and treating persistent AF patients based on the underlying pathophysiology of their AF disease. Objective: The primary objective of the FLOW-AF trial is to evaluate the reliability of the EGF algorithm technology (Ablamap software) to identify AF sources and guide ablation therapy in patients with persistent AF. Methods: The FLOW-AF trial (NCT04473963) is a prospective, multicenter, randomized clinical study in which patients with persistent or long-standing persistent AF who have failed prior PV isolation (PVI) undergo EGF mapping after confirmation of intact PVI. In total, 85 patients will be enrolled and stratified based on the presence or absence of EGF-identified sources. Patients with an EGF-identified source above the predetermined activity threshold of ≥26.5% will be randomized in a 1:1 fashion to PVI only vs PVI + ablation of EGF-identified extra-PV sources of AF. Results: The primary safety endpoint is freedom from serious adverse events related to the procedure through 7 days following the randomization procedure; and the primary effectiveness endpoint is the successful elimination of significant sources of excitation with the target parameter the activity of the leading source. Conclusions: The FLOW-AF trial is a randomized study designed to evaluate the ability of the EGF mapping algorithm to identify patients with active extra-PV AF sources.

12.
Diabetes ; 72(9): 1187-1192, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37352012

RESUMO

With rising incidence and prevalence of type 2 diabetes, prevention including identification of prospective biomarkers becomes increasingly relevant. Although ketone bodies recently received a renewed interest as potential biomarkers, data linking these metabolites to diabetes risk are scarce. Therefore, the present prospective study investigated a potential association between fasting ketone bodies and incident type 2 diabetes in the general population. This study from the PREVEND cohort included 3,307 participants from the general population initially free of diabetes or impaired fasting glucose. Baseline fasting ketone body concentrations were measured by nuclear magnetic resonance spectroscopy. One hundred twenty-six participants (3.8%) developed type 2 diabetes during a median (interquartile range) follow-up of 7.3 (6.3-7.6) years. In Kaplan-Meier analysis, sex-stratified ketone body levels strongly positively associated with incident type 2 diabetes, which was confirmed in Cox regression analyses adjusted for several potential confounders. There was no significant interaction by sex. Both 3-ß-hydroxybutyrate and acetoacetate+acetone individually associated with incident type 2 diabetes. In conclusion, fasting plasma ketone body levels are strongly positively associated with incident type 2 diabetes in the general population independent of several other recognized risk factors. These results may have important implications for diabetes prevention including dietary strategies. ARTICLE HIGHLIGHTS: The identification of biomarkers that predict type 2 diabetes is increasingly relevant for personalized medicine strategies. Data regarding ketone bodies and incident type 2 diabetes are scarce. This study shows that ketone bodies, either combined or as individual subspecies, are strongly associated with incident type 2 diabetes in the general population, independent of potential confounders. These results may have important implications for diabetes prevention including dietary strategies.


Assuntos
Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/epidemiologia , Corpos Cetônicos , Glicemia/metabolismo , Estudos Prospectivos , Ácido 3-Hidroxibutírico , Jejum , Biomarcadores
13.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1368-1378, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37141904

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are frequently used for primary and secondary prevention in patients with cardiomyopathies due to different etiologies. However, long-term outcome studies in patients with noncompaction cardiomyopathy (NCCM) are scarce. OBJECTIVES: This study summarizes the long-term outcome of ICD therapy in patients with NCCM compared with those with dilated cardiomyopathy (DCM) or hypertrophic cardiomyopathy (HCM). METHODS: Prospective data from our single-center ICD registry were used to analyze the ICD interventions and survival in patients with NCCM (n = 68) compared with patients with DCM (n = 458) and patients with HCM (n = 158) from January 2005 to January 2018. RESULTS: This NCCM population with an ICD for primary prevention comprised 56 (82%) patients with a median age of 43 years and 52% males, compared with 85% in patients with DCM and 79% in patients with HCM (P = 0.20). During a median follow-up of 5 years (IQR: 2.0-6.9 years), appropriate and inappropriate ICD interventions were not significantly different. Nonsustained ventricular tachycardia during Holter monitoring in patients with NCCM was the only significant risk factor for appropriate ICD therapy in patients with NCCM, with a HR of 5.29 (95% CI: 1.12-24.96). The long-term survival was significantly better in the univariable analysis in the NCCM group. However, there was no difference in multivariable Cox regression analyses between the cardiomyopathy groups. CONCLUSIONS: At 5 years of follow-up, the rate of appropriate and inappropriate ICD interventions in NCCM was comparable to that in DCM or HCM. In multivariable analysis, no differences in survival were found between the cardiomyopathy groups.


Assuntos
Cardiomiopatias , Cardiomiopatia Dilatada , Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Masculino , Humanos , Adulto , Feminino , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Estudos Prospectivos , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Fatores de Risco
14.
J Interv Card Electrophysiol ; 66(9): 2103-2111, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37076739

RESUMO

BACKGROUND: Catheter ablation (CA) has become a well-established first-line therapy for a broad spectrum of arrhythmias, including atrial tachycardias (ATs). In this study we aimed to assess the performance of the integrated novel high-resolution new generation noncontact mapping system (AcQMap) with robotic magnetic navigation (RMN) system in CA procedures for patients with ATs including comparing patient subgroups based on the utilized mapping modality, arrhythmia mechanism, localization and type of procedure. METHODS: All patients undergoing CA for AT using the AcQMap-RMN system were included. Procedural safety and efficacy were characterized by intra- and post-procedural complications. Acute procedural success and the long-term outcome were assessed in the overall group and in the subgroups. RESULTS: A total number of 70 patients were referred for CA with atrial arrhythmias including 67 AT/AFL (mean age 57.1 ± 14.4 years), and 3 additional patients with inappropriate sinus tachycardia. Thirty-eight patients had de novo AT, 24 had post-PVI AT including 2 patients with perinodal AT, and 5 had post-MAZE AT. Two patients (2.9%) suffered post-procedural complications including 1 patient with groin hematoma and 1 patient with a transient ischemic attack. Acute success was achieved in 63/67 (94.0%) procedures. Thirteen patients (19.4%) had documented recurrence at the end of the 12-months follow-up period. The performance of AcQMap was equally good in focal vs. reentry mechanisms (p = 0.61, acute success), in the left and right atrium (p = 0.21). CONCLUSIONS: AcQMap-RMN integration might improve success rates in CA of ATs with low number of complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Procedimentos Cirúrgicos Robóticos , Taquicardia Supraventricular , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Resultado do Tratamento , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgia , Ablação por Cateter/métodos , Fenômenos Magnéticos
15.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37072340

RESUMO

AIMS: RECOVER AF evaluated the performance of whole-chamber non-contact charge-density mapping to guide the ablation of non-pulmonary vein (PV) targets in persistent atrial fibrillation (AF) patients following either a first or second failed procedure. METHODS AND RESULTS: RECOVER AF was a prospective, non-randomized trial that enrolled patients scheduled for a first or second ablation retreatment for recurrent AF. The PVs were assessed and re-isolated if necessary. The AF maps were used to guide the ablation of non-PV targets through elimination of pathologic conduction patterns (PCPs). Primary endpoint was freedom from AF on or off antiarrhythmic drugs (AADs) at 12 months. Patients undergoing retreatment with the AcQMap System (n = 103) were 76% AF-free at 12 months [67% after single procedure (SP)] on or off AADs (80% free from AF on AADs). Patients who had only received a pulmonary vein isolation (PVI) prior to study treatment of non-PV targets with the AcQMap System were 91% AF-free at 12 months (83% SP). No major adverse events were reported. CONCLUSION: Non-contact mapping can be used to target and guide the ablation of PCPs beyond the PVs in persistent AF patients returning for a first or second retreatment with 76% freedom from AF at 12 months. The AF freedom was particularly high, 91% (43/47), for patients enrolled having only a prior de novo PVI, and freedom from all atrial arrhythmias for this cohort was 74% (35/47). These early results are encouraging and suggest that guiding individualized targeted ablation of PCPs may therefore be advantageous to target at the earliest opportunity in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Retratamento , Antiarrítmicos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
16.
Front Pediatr ; 11: 1085730, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36911028

RESUMO

Background and purpose: Electromechanical dyssynchrony, manifested by right bundle branch block and regional wall mechanical dysfunction, contributes to inefficient RV function in repaired Tetralogy of Fallot (ToF). This study aims to evaluate the synchronicity of multiple RV walls using two-dimensional multi-plane echocardiography (2D-MPE) in order to augment current understanding of the mechanisms behind RV dyssynchrony. Methods: Sixty-nine adult ToF patients [aged 33 (23-45) years; 61% male] and twenty-five matched healthy controls underwent deformational analysis of the RV lateral, anterior, inferior and septal walls following 2D-MPE acquisitions. RV synchronicity was assessed by the intra-RV deformation delay between each basal RV wall and mid-septal segment in addition to mechanical dispersion calculated across four, six and eight segments (MD). Results: All RV wall-septum delays plus MD-4 and MD-6 indices were significantly greater in ToF patients compared to healthy controls (p < 0.001-0.03). In ToF patients, the lateral and anterior RV walls were last to reach peak deformation and anterior wall longitudinal strain was lower (p = 0.001). Post systolic shortening of at least one RV wall segment was identified in 19 (28%) ToF patients. Despite similar ECG characteristics, lateral and anterior wall-septum delays were significantly longer in patients with greater degrees of dyssynchrony (73 [37-108]ms vs. 37 [0-63]ms, p = 0.006; 91 [52-116]ms vs. 41 [1-69]ms, p = 0.013), although RV ejection fraction (RVEF) was not significantly lower. MD-4 and MD-8 indices displayed moderate negative associations with RVEF, strengthened by inclusion of lateral wall longitudinal strain (r = 0.64/0.65; p ≤0.01). Conclusion: RV dyssynchrony in ToF is characterised by electromechanical delays between the lateral, anterior and septal walls, with anterior wall dysfunction likely associated with surgical repair of the RV outflow tract. Prospectively, 2D-MPE may have an emerging role evaluating RV mechanical response to electrical resynchronisation therapy.

17.
19.
Expert Rev Med Devices ; 20(2): 85-97, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36695092

RESUMO

INTRODUCTION: The 2018 ESC Syncope guidelines expanded the indications for an insertable cardiac monitor (ICM) to patients with unexplained syncope and primary cardiomyopathy or inheritable arrhythmogenic disorders. AREAS COVERED: This review article discusses the clinical evidence for using an ICM for risk stratification in different patient populations including Brugada syndrome, long QT syndrome, hypertrophic cardiomyopathy, arrhythmogenic right ventricular cardiomyopathy, cardiac sarcoidosis, and congenital heart disease. EXPERT OPINION: Clinical data on the usefulness of ICMs in different patient populations is limited but most studies demonstrate early detection of clinically relevant arrhythmias, such as nonsustained ventricular tachycardia or atrial fibrillation. It is important to emphasize that the study populations usually comprise selected populations where conventional diagnostic methods fail to clarify the mechanism of symptoms. The effect of an ICM on prognosis by earlier detection of arrhythmias is difficult to demonstrate in populations with rare disease. Risk stratification in patients with cardiomyopathy or inheritable arrhythmogenic disorders remains a niche indication for ICMs. The most important indication for an ICM remains unexplained syncope in patients at low risk of SCD. Given the device costs and uncertain clinical value of device-detected arrhythmias, it is unclear whether it is also useful in non-syncopal patients.


Assuntos
Fibrilação Atrial , Síndrome de Brugada , Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Humanos , Fibrilação Atrial/diagnóstico , Síncope/diagnóstico , Cardiomiopatia Hipertrófica/diagnóstico , Morte Súbita Cardíaca
20.
J Interv Card Electrophysiol ; 66(4): 951-959, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36282368

RESUMO

BACKGROUND: Short runs of atrial tachycardias (ATs) and infrequent premature atrial contractions (PACs) are difficult to map and ablate using sequential electrophysiology mapping techniques. The AcQMap mapping system allows for highly accurate mapping of a single atrial activation. OBJECTIVES: We aimed to test the value of a novel dipole charge density-based high-resolution mapping technique (AcQMap) in the treatment of brief episodes of ATs and PACs. METHODS: Data of all patients undergoing catheter ablation (CA) using the AcQMap mapping system were reviewed. RESULTS: Thirty-one out of 219 patients (male n = 8; female n = 23) had short runs of ATs (n = 23) and PACs (n = 8). The mean procedural time was 155.3 ± 46.6 min, with a mean radiation dose of 92.0 (IQR 37.0-121.0) mGy. Total radiofrequency application duration 504.0 (271.0-906.0) s. Left atrial localization of ATs and PACs was identified in 45.1% of the cases, right atrium localization in 45.1%, and septal origins in 9.8% of the cases. Acute success was achieved in 30/31 (96.8%), and recurrence during the follow-up developed in six patients (19.4%), including four patients with PACs and two patients with short-lived ATs. One patient presented procedure-related groin hematoma as minor complication. CONCLUSION: Brief episodes of highly symptomatic ATs and infrequent PACs can be mapped using charge density mapping and successfully ablated with high acute and long-term success rates.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Taquicardia Supraventricular , Humanos , Masculino , Feminino , Complexos Atriais Prematuros/cirurgia , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Fibrilação Atrial/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...